Automatic cleaning operation steps:
1. Preparation of deionized water: use electrodialysis device and ion exchange resin tank to prepare deionized water.
2. Conductivity test: Use a conductivity tester to test the conductivity of the water after electrodialysis and ion exchange resin tanks. If both meet the index requirements, it can be used for water cleaning.
3. Introduce the water washing machine: introduce the deionized water in the water storage tank to the water washing machine.
4. Set the parameters of the washing machine: the washing room and the rinsing room are set to 60±10℃; the drying room is set to 60℃~90℃.
5. Setting the chain speed: generally control the chain speed at 50~150cm/min.